269 Frost Protection Accessories Frost Protection Heating Pipe with Thermostat • keeps your water line frost-free to -45 ° C • integrated frost protection thermostat (switch-on temperature approx. +3 °C, switch-off temperature approx. +13 °C) • not suitable for heating pipes • do not insulate the thermostat when adding insulation • protect the area animals could chew on with a bite protector • mechanical strength class M1 (not suitable for gutters or other applications with mechanical load) • VDE-approved heating pipe (except 49 m heating pipe) • 230 V • VDE tested • Connection cable length: 2 m • Voltage: 230 V • IPX7 frost-protected down to max. -45 °C Do not mount in animal feed area unprotected - use only 24-volt heating cable. Do not shorten the heating cable! Ref. no. Heating output Heating cable length Plug type € 223582 16 W 1 m Safety Plug E + F 1/16 640 223585 32 W 2 m Safety Plug E + F 1/16 640 223586 64 W 4 m Safety Plug E + F 1/16 640 223587 128 W 8 m Safety Plug E + F 1/16 576 223588 192 W 12 m Safety Plug E + F 1/16 192 223590 224 W 14 m Safety Plug E + F 1/16 192 223589 288 W 18 m Safety Plug E + F 1/10 120 223591 384 W 24 m Safety Plug E + F 1/10 120 223592 592 W 37 m Safety Plug E + F 1/5 165 223593 784 W 49 m Safety Plug E + F 1/5 60 Pipe Insulation max. 13 mm Insulating cover Heating cable Frost-protection heating lines • prevent water pipes from freezing • thermostat in the heating cable switches the cable on automatically What to remember about 230 V heating cables: • installation must be carried out by a qualified professional in accordance with VDE0100 • always attach the heating cable to the underside of the pipe • the water pipe must be earthed • 230 V heating cables are ready to connect and should be connected to a power supply with a 30 mA residual current circuit breaker • the heating cables must not be shortened • the heating cable must not be 600 mm shorter or longer than the pipe section to be heated • excess length can be wound around the end of the pipe (note that a winding distance of at least 50 mm must be maintained between coils) • do not bend heating cables and note the maximum bending radius of approx. 20 mm • heating cables can be secured to the pipe with insulating tape or aluminium tape (222809) • the heating cable must only be used on plastic resistant water lines approved for hot water that are always filled with water • if using plastic pipes, wrap aluminium tape (222809) around the pipe before routing the heating cable • if using plastic pipes, please pay attention to the separate, specific assembly instructions • insulate the pipeline and heating cable with non-flammable insulation of max. 13 mm • attach the heating cable thermostat to the coldest part of the pipe • do not use 230 V heating cables in the bite area of animals Are you looking for a gutter heating pipe or heating pipe of a higher strength class? Further heating pipes can be found in the House and Garden section on page 272. not for sale in UK not for sale in UK not for sale in UK not for sale in UK not for sale in UK not for sale in UK not for sale in UK not for sale in UK not for sale in UK not for sale in UK
RkJQdWJsaXNoZXIy MTUxMjAyMw==