Agricultural Equipment and Supplies 2024

251 Frost Protection Accessories Frost protection heating pipe with thermostat • keeps your water line frost-free to -45 ° C • integrated frost protection thermostat (switch-on temperature approx. +3 °C, switch-off temperature approx. +13 °C) • not suitable for heating pipes • do not insulate the thermostat when adding insulation • Protect the area animals could chew on with a bite protector • Mechanical strength class M1 (not suitable for gutters or other applications with mechanical load) • VDE-approved heating pipe (except 49 m heating pipe) • 230 V • Connection cable length: 2 m • Voltage: 230 V • VDE tested • IPX7 frost-protected down to max. -45 °C Do not mount in animal feed area unprotected - use only 24-volt heating cable. Do not shorten the heating cable! ​ Ref. no. Heating output Length Plug type ​ ​ € 223582 16 W 1 m Safety Plug E + F 1/16 192 ​ 223585 32 W 2 m Safety Plug E + F 1/16 192 ​ 223586 64 W 4 m Safety Plug E + F 1/16 192 ​ 223587 128 W 8 m Safety Plug E + F 1/16 192 ​ 223588 192 W 12 m Safety Plug E + F 1/16 192 ​ 223590 224 W 14 m Safety Plug E + F 1/16 192 ​ 223589 288 W 18 m Safety Plug E + F 1/10 120 ​ 223591 384 W 24 m Safety Plug E + F 1/10 120 ​ 223592 592 W 37 m Safety Plug E + F 1/5 75 ​ 223593 784 W 49 m Safety Plug E + F 1/5 60 ​ Pipe Insulation max. 13 mm Insulating cover Heating cable Frost-protection heating lines • prevent water pipes from freezing • thermostat in the heating cable switches the cable on automatically What to remember about 230 V heating cables: • installation must be carried out by a qualified professional in accordance with VDE0100 • always attach the heating cable to the underside of the pipe • the water pipe must be earthed • 230 V heating cables are ready to connect and should be connected to a power supply with a 30 mA residual current circuit breaker • the heating cables must not be shortened • the heating cable must not be 600 mm shorter or longer than the pipe section to be heated • excess length can be wound around the end of the pipe (note that a winding distance of at least 50 mm must be maintained between coils) • do not bend heating cables and note the maximum bending radius of approx. 20 mm • heating cables can be secured to the pipe with insulating tape or aluminium tape (222809) • the heating cable must only be used on plastic resistant water lines approved for hot water that are always filled with water • if using plastic pipes, wrap aluminium tape (222809) around the pipe before routing the heating cable • if using plastic pipes, please pay attention to the separate, specific assembly instructions • insulate the pipeline and heating cable with non-flammable insulation of max. 13 mm • attach the heating cable thermostat to the coldest part of the pipe • do not use 230 V heating cables in the bite area of animals Are you looking for a gutter heating pipe or heating pipe of a higher strength class? Further heating pipes can be found in the House and Garden section on page 305.

RkJQdWJsaXNoZXIy MTUxMjAyMw==