Water bowl technology for stable and pasture

11 Frost Protection Drinkers HP20, item No. 222050 230 Volt / 73 Watt, with auxiliary pipe heating HP20, item No. 222040 230 Volt / 31 Watt H10, item No. 222005 24 Volt / 50 Watt HP20, item No. 222045 24 Volt / 31 Watt HP20, item No. 222055 24 Volt / 73 Watt, without auxiliary pipe heating Water line Supply line 230 Volt (three-wire) Heating cable 230 Volt Supply line 24 Volt (two-wire) Heating cable 24 Volt heated supply line Installation diagram shown without insulation and bite protection! Heating cable, 3 m 24 Volt, 30 W Item No. 223581 Earth connection on the metal pipe, when using pipe-laying heating cables > 48 V Socket, 230 V each separately fused with: - B10 A or B16 A circuit breaker - Residual current circuit breaker 30 mA Heating cable, 3 m 24 Volt, 30 W Item No. 223581 Junction box Junction box Junction box Optional: Frost protection thermostat, item No. 222794 Switching the entire heating installation on and off. Must be positioned in the coldest spot in the stall. Heating cable, 12 m 230 Volt, 192 W Item No. 223588 Minimum distance 0.5 m from the thermostat of one 230 V heating cable to the next heating cable Safety transformer 200 Watt, item No. 222797 Calculation: (1 x 50 W + 1 x 31 W+ 2 x 30 W) x 1.15 = 163 W Safety transformer 300 Watt, item No. 222626 Calculation: (3 x 73 W + 1 x 30 W) x 1.15 = 287 W 230 Volt installations must be configured by a qualified specialist. Filter unit and shutoff device Supply line coming from a secure separation according to DIN EN 1717 - Type AA, Type AB 230 V 1 24 V 1 1 1 1 1

RkJQdWJsaXNoZXIy MTUxMjAyMw==